Jinan Winner Particle Instrument Stock Co., Ltd. Company Logo Jinan Winner Particle Instrument Stock Co., Ltd.

WINNER2006B Intelligent Wet Laser Particle Size Analyzer

Contact Now* Send an Inquiry to this supplier.
or
Start Order * Name your price

Contact us

Jinan Winner Particle Instrument Stock Co., Ltd.
[China]

Address
Building F, North Area, University Science Industry Park, Gao'xin District Jinan Shandong
Phone
86-0531-88876213
Contact name
Annie Zhang

Quick Information

  • Brand Name: Winner
  • Place of Origin: China
  • Model Number : Winner2006B
  • Accuracy Error : <0.5%
  • Repeatability Error : <0.5%
  • Measurement Range : 0.1-1000um
  • Light Source : Semiconductor laser

Description

Overview:

Winner2006 intelligent full automatic laser diffraction particle size analyzer with principle of Mie Scattering to precisely determine the particle size distribution from 0.1μm to 1000μm. It enables you understand materials well, such as abrasives, adhesives, agrochemical,barite, Batteries, Bentonite, Boron Carbide, Brucite, Bubble, Calcite, Calcium Carbonate, Carbon Black, Catalysts, Cement, Ceramics, Chemicals, Clay, Coal, Coatings, Corundum, Cosmetics, Diamond Powder, Dolomite, Diatomite,Emulsion, Environmental, Explosives, Ferrite, Flour, Fluorescent, Fluorite, Food & Beverage, Food Additive,Graphite, Grinding, Inks, Kaolin, Medicine, Metal Powder, Mica, Milling, Minerals,Oxides,Paints, Paper, Petrochemical, Pharmaceuticals, Pigments, Plaster, Plastics, Polymers,Quartz,Refractory, Resins, Silica, slurry, Soil Sediments, Starch, Sulfur, Synthetics, Talc, Toners, Tourmaline,Wollastonite, Zeolite, Zirconium Silicate etc etc. Industry.


Main Specifications:

                    

                       Model Name


    Winner2006A


                  Winner2006B


                           Standard


                     GB/T19077.1-2016;ISO 13320:2009;Q/0100JWN001-2024


                           Size range


                       0.01-1000um


                             0.1-1000um

Accuracy error

                      ≤0.5% (Deviation of D50 on national standard sample)

Repeatability error

           ≤0.5% (Deviation of D50 on national standard sample)

 

 

Laser parameters


                  Main laser source: high-performance laser λ= 632nm, power P>2mw

Auxiliary laser source: semiconductor laser λ=405nm, power P>2mW

            

    none

 

 

 

Dispersion method

 

              Ultrasound

 

                     Frequency f=40KHZ, ultrasonic P=60W, time adjustable

 

                  Stir

                  

                             Speed 0-3000rpm   speed optional


                 cycle

       

               Rated flow 17L/min; rated power P=15W

 

              Sample cell


        

                           Capacity 450ML

 

Operating mode

Software operation/fully automatic operation mode (switchable)/SOP one-click fully automatic test

            

         Optical path alignment system

 

                              Fully automatic centering system


                     Fastest test speed


                           <10s

Product volume

92.9cm ×49.4cm×39.5cm

Product weight

40kg


Main Features


1, Advanced design of optical path

A patented technique of Fourier transform of converging light released the scattered light at large-scattering-angles from the restriction of the aperture of the Fourier lens. The focal length is reduced to enhance the resolution of the instrument, and ring shaped of multi-element silicon photo-diode ensure gathering all the light signals of particles, highly improve the resolution.


2, Built-in intelligent liquid dispersion units:

We carefully aligned the stirring set-up, the ultrasonic dispersing unit and the sample circulation pipes, and fixed them inside the instrument. Such a built-in design effectively prevents the inhomogeneous dispersion and sedimentation of big particles, which can be observed in the designs that these dispersing units are separated from the instruments, where the sample circulation pipes are therefore too long, The sample will be sufficiently dispersed.


3, Unconstrained free fitting analysis software patent techniques:

The particle analysis software uses a unique unconstrained data fitting analysis patent technique that we developed to obtain data of real particle size distribution, this is particularly important for researchers.


4, Modern measurement control:(Intelligent SOP Operation)

Users can perform all measurement procedures by simply operating on the PC and have ideal results in a very short time.


5, User-friendly Operation:

manual mode and the automatic mode, freely choose, to measure according to the sample features. In some conditions (e.g. the sample have unknown features or there are special requirements for the measurements), users can make a test measurement in the manual mode first, and after having an idea of the sample features and the measurement conditions, measure the samples in the automatic mode.


6, Three dimension automatic optical path alignment system:

A precise four phase hybrid stepping motor automatically aligns the optical path and can adjust it at any moment, precision is up to 0.1um, This releases users from manual adjusting the optical path and improved accuracy and stability of the measurement results.


7, Quick particle size distribution measurements:

set " automatic" mode, all operation procedures are performed automatically,automatic water supply, automatic ultrasonic sample, stirring, circulation,background testing, sample testing,analysis , draining and cleaning, which significantly reduces the time for measurements, the full process < 2 minutes.


8, Data analysis:

Errors in the data are rejected and the measurement results are automatically processed. Manual data processing is not necessary and the output is more standard.


Ⅱ test analysis view

After testing, if necessary, to select records generated an average result, the system analyzes the formation of the recording. When the automatic mode test, without data processing, forming and maintaining a comprehensive system automatically analyzed test records.




Scheme:

Winner-2005 Intelligent Laser Particle Size Analyzer

Adopt Patents Technology:

● Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,

● Three dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.

● MIE scattering principle application patent No.- ZL 2013 2 0812021.4.

● Dual laser beam orthogonal application is protected by patent No.-ZL 2007 2 0025702.0

● Wet circulation installation is protected by patent No.-ZL2010 2 0593526.2


Application

Winner-2005A Intelligent Laser Particle Size Analyzer



Certificates

  • CE : M2026206C133438
  • FDA : 261047000

Price

  • Delivery Port : Qingdao

Packaging & Delivery

  • Delivery Lead Time : 5-7 days
  • Supply Ability : 300 sets per Month

Product Image

  • 1WINNER2006B Intelligent Wet Laser Particle Size Analyzer image 1
  • 2 WINNER2006B Intelligent Wet Laser Particle Size Analyzer image 2
  • 3 WINNER2006B Intelligent Wet Laser Particle Size Analyzer image 3

Send an Inquiry to this supplier

Send an Inquiry to this supplier
* From
  To Annie Zhang
Jinan Winner Particle Instrument Stock Co., Ltd.
* Buying Product
- Please enter your specific buying item.
e.g. 42 inch LCD TV, leather executive chair
Category : Other Measuring & Analysing Instruments
* Message

Use English only Max. 2000 characters. (Min. 20)

Send
EC21.com does not guarantee the validity of product information or the credentials of sellers.

Browse: Manufacturer Directory Premium Suppliers Site Map

About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy

Copyright (c)1997-2026 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese

Business Registry Number: 120-86-03931 | Mall order sales Registration Number: 강남-5838